Amalgam technology

Picture

T5 fluorescent lamps HO CONSTANT, as well as compact fluorescent lamps OSRAM DULUX L CONSTANT and OSRAM DULUX T/E CONSTANT, show, thanks to amalgam technology, constant high luminous flux over a wide temperature range.

More efficient and energy-saving lighting for T5 and compact fluorescent lamps.

 

Compare:

  • Conventional T5 lamps:
    > 90 % luminous flux between approx. 25 °C and 50 °C (max. luminous flux at 35 °C)

  • CONSTANT lamps:        
    > 90 % luminous flux between 5 °C and 70 °C
    (except LUMILUX T5 HO 49 W CONSTANT: 20 °C and 80 °C)

 

Your benefits

  • Flicker-free pre-heat start
  • More light than from conventional HO lamps
  • Higher system efficiency over a wide temperature range

High luminous flux over a wide temperature range

null

The extended temperature range of the OSRAM T5 HO CONSTANT (b)
compared to the one of LUMILUX T5 HO (a)

Start-up of a CONSTANT lamp

With T5 HO CONSTANT amalgam lamps (24 W, 39 W, 49 W, 54 W, 80 W), the mercury vapor pressure and hence the luminous flux is determined by the composition and the temperature of the amalgam. The following happens during a start-up:

Up to 10 seconds

  • Start-up amalgam warms up quickly
  • Mercury evaporates from the start-up amalgam
  • The lamp is bright at its ends (where enough mercury vapor is present)
    and pink towards the center

Up to 3 minutes (HO 49 W CONSTANT: up to 5 minutes)

  • Mercury from start-up amalgam flag is completely evaporated
  • The brightness of the lamp expands from its ends towards the center
  • Operational amalgam warms up and gains equilibrium with the mercury pressure in the lamp

Due to the technical superiority of amalgam lamps that allows them to efficiently operate at a wider range of ambient temperature
(>90 % of the luminous flux in the temperature range of +5 °C to 70 °C / +20 °C to 80 °C for the T5 HO 49 W CONSTANT), 
the start-up time to reach a stable state is extended.

It is always important to consider conditions such as drafts, ambient temperature, emergency requirements, dim settings, etc.

null

Start-up of a CONSTANT lamp

Picture

Dimming amalgam lamps

  • Shorter start-up due to Power Boost 
  • Optimal lamp operation even at low dimmer settings
Read More
 

The products: 

Picture

LUMILUX T5 HO HIGH OUTPUT CONSTANT

HO CONSTANT is the first fluorescent lamp that has been optimized for a wider than usual temperature range.

Read More
 
Picture

OSRAM DULUX L CONSTANT

The innovative compact fluorescent lamp operates using new high-temperature amalgam technology.

Read More
 
Picture

OSRAM DULUX T/E CONSTANT

OSRAM DULUX T/E CONSTANT was developed especially for interior lighting, in particular for high ambient temperatures, e.g. in narrow downlights.

Read More
 
Picture

ECGs for fluorescent and compact fluorescent lamps

Optimal lamp operation and economy

Read More
 

HO CONSTANT Contact

For project applications where certain dimming levels are required, please send us an e-mail to discuss if a special release is possible.

Read More